FALCON III > Specification
  Sensor Head

Beam deflection:         Fixed, fiber based
Field of view: 28 degrees fixed
Measurement rate: 50 kHz - 125 kHz
Operating altitude: 30 m - 2,500 m
Beam divergence: 0.7 mrad

Range capture:

Up to nine per pulse
Full waveform digitization as opt.

Intensity capture: 12 bit dynamic range
Scan frequency: 165 Hz - 415 Hz
Echo separation: 2.0 m
Eye save: > 0.27 m
Swath width: 46 % of op. altitude
Range resolution: 0.010 m
Vertical accuracy: < 0.10 m (absolute)
Horizontal accuracy: < 0.20 m (absolute)
Spot distribution: Swing Mode
Weight: 40 kg
Dimensions sensor:      40 x 40 x 45 cm

Computer Rack

Log time:                    > 8 h @ 125 kHz
Power: 28 V DC, 15 A max.
Positioning system: Applanix POS/AV 410
Weight: 25 kg
Dimensions computer:   40 x 40 x 45 cm

Line Scanner (Option)

Field of view:                30 degrees
Channels: Four (R, G, B, NIR)    
Line rate: Up to 300 Hz
Pixel: 4 x 2048 per line
Image pixel size: Down to 0.05 m
Image scale: 1:500 to 1:10,000
Position accuracy:           Down to 0.05 m



Print version